Micropiles

Bar Properties

DYWIDAG THREADBAR ® Reinforcing Steel ASTM A615 (Grade 75)

THREADBAR ® Designation Maximum THREADBAR ® Diameter Yield Stress

( fy)
Cross Section Area 
(As)
Yield Load 

(fy * As)
Nominal Weight
[in] [mm] [in][mm][ksi] [Mpa] [in2] [mm2] [kips][kN][lbs/ft] [kg/m]
#11 36 1.614175 517 1.561,006117.05205.31 7.90
#14 43 1.864775 517 2.251,452168.87517.65 11.38
#18 57 2.506475 517 4.002,581300.01,33513.60 20.24
#20 63 2.726980 552 4.913,168393.01,74816.70 24.85
#24753.1881755177.064,555529.52,35524.0935.85
#28903.6894755179.626,207721.53,20932.7948.79

NOTE: Maximum test load = 90% of the yield load; Mill length = 60'-0'' for #6 through #24 bars and 48'-0'' for '28 bars

DYWI ® Drill  Hollow Bar Properties

Bar DesignationNominal Outer DiameterAverage Yield Stress
(fy)
Average Ultimate Tensile Stress
(fy)
Average Cross Section Area
(As)
Yield Load 

(fy* As)
Ultimate Load

(fu* As
Nominal Weight
[in][mm][ksi][MPa][ksi][MPa][in2][mm2][kips][kN][kips][kN][lbs/ft][kg/m]
R51L 2.00 51 865961067291.177541014501245503.975.90
T40N 1.5740896141127721.328541185251486604.506.70
R51N 2.00 51886081127721.611,0361426301808005.448.10
T76N 3.0076815591087453.322,1452701,2003601,60011.2916.80
T76S 3.00 76875991107583.882,5043371,5004271,90013.2419.70

NOTE: Maximum allowable, temporary test load is 100% of the yield load. Average cross section area is based on average internal diameter of the bar. The ultimate and yield load capacity are measured values. The ultimate tensile and yield stress are calculated average values. Mill length is 9‘-10“ (3m). Longer lengths can be special order.

DYWIDAG THREADBAR ® Prestressing Steel ASTM A722 (Grade 150)

THREADBAR ® DesignationMaximum 
THREADBAR ® Diameter
Ultimate Stress

(fu)
Cross Section Area

(As)
Ultimate Load

(fu * As)
Nominal Weight
[in][mm][in][mm][ksi][MPa][in2][mm2][kips][kN][lbs/ft][kg/m]
1-1/4" 32 1.4436 1501,0341.25806187.58344.396.53
1-3/8 "36 1.63411501,0341.581,019237.01,0545.568.27
1-3/4" 46 2.01511551,0692.581,664400.01,7799.2213.72
2-1/2" 66 2.79711501,0345.163,355774.03,44318.2026.36
3" *753.15801501,0346.854,4191,027.04,56824.0935.85

NOTE: Maximum test load = 80% of the ultimate load; Mill length = 60'-0" for 1", 1¼" and 1-3/8 " Threadbars and 45'-0" for 1¾", 2½" and 3" bars

* 3" (75 mm) THREADBAR® is not covered by ASTM A722