Downloads read more ...
Brochure DYWIDAG Post-Tensioning Systems,
Filesize:1.8 MB
Filesize:1.8 MB
Brochure What is Post-Tensioning,
Filesize:17.6 kB
Filesize:17.6 kB
Brochure ASBI Grouting Practices,
Filesize:67 kB
Filesize:67 kB
Multistrand Post-Tensioning System
Plate Anchorage SD

- 1 - Grouting Accessories 2 - SD-Plate Anchorage 3 - Spiral 4 - PE-Trumpet 5 - Duct 6 - Wedge 7 - Duct Coupler
| Tendon Size | 3-0.6" \ or 4-0.5" | 4-0.6" \ or 5-0.5" | 5-0.6" \ or 7-0.5" | 6-0.6" \ or 8-0.5" | 7-0.6" \ or 9-0.5" | |||||
| Combination Plate D | 4-15/16 \ 125 | 5-5/16 \ 135 | 5-7/8 \ 150 | 6-1/2 \ 165 | 6-11/16 \ 170 | |||||
| E | 5-1/2 \ 140 | 6-5/16 \ 160 | 7-1/16 \ 180 | 8-1/16 \ 205 | 8-1/2 \ 215 | |||||
| H | 1-5/8 \ 41 | 1-5/8 \ 41 | 1-9/16 \ 40 | 1-3/4 \ 44 | 1-3/4 \ 44 | |||||
| Transition Ø | 2-9/16 \ 65 | 2-15/16 \ 75 | 3-3/8 \ 85 | 3-3/4 \ 95 | 3-3/4 \ 95 | |||||
| L | 11-3/8 \ 290 | 10-7/16 \ 265 | 14 \ 355 | 15-15/16 \ 405 | 15-15/16 \ 405 | |||||
| Pocket Former A | 6-1/2 \ 165 | 6-1/2 \ 165 | 7-1/16 \ 180 | 7-7/8 \ 200 | 7-7/8 \ 200 | |||||
| B | 7-5/16 \ 185 | 7-5/16 \ 185 | 8-1/4 \ 210 | 9-7/16 \ 240 | 9-7/16 \ 240 | |||||
| C | 3-15/16 \ 100 | 3-15/16 \ 100 | 3-15/16 \ 100 | 4-5/16 \ 110 | 4-5/16 \ 110 | |||||
| Duct ID | 1-9/16 \ 40 | 1-13/16 \ 46 | 2-1/16 \ 52 | 2-7/16 \ 62 | 2-7/16 \ 62 | |||||
| L2 | 8 \ 200 | 8 \ 200 | 8 \ 200 | 8 \ 200 | 8 \ 200 | |||||
| All dimensions are nominal and are expressed in inch \ mm. | ||||||||||